Products

UPS

XPS-NSI

10, 15, 20, 30, 40, 50, 60, 75, 80, 100

System


Operation system
Control system
Double Conversion
(On Line) System
DSP (Digital Signal
Processor) Control

Rated capacity


1phase 10 ~ 100kVA

(Designated at the time of purchase)

Input(Rectifier/Sine waveform of charger part)


Input
voltage
3phase 380V
(Select 208/220/440/480V)
Input
constant
3phase 3wire / 3phase 4wire
Input
frequency
50 / 60Hz
Input
distortion rate
3% or less voltage,
5% or less current
Input
power
factor
0.99 or more
Control
system
PWM Converter
(element use : IGBT)

Storage battery


Rated
voltage
DC 360V
(DC 110, 220, 240V, etc., can be changed)
Quantity
DC 360V - 12V 30Cells or
2V 180Cells

Output(Inverter part)


Output
voltage
1phase 220V
(Select 110, 120, 208, 230V)
Voltage
stability
±2% or less
Output
waveform
sine wave
Output
constant
1phase 2wire
Output
frequency
50 / 60Hz
Frequency stability
±0.1% or less
Output
distortion rate 
→ linear load (±3% or less)

→ non-linear load (±5% or less)

Overload capacity
Rated load 125% 10 minutes
Transient response
±5% or less
Transient
response
time
50ms or less
(return within ±2%)
Load
power
factor
0.8 Lag
Overall
efficiency
88% or more
Control
system
PWM Inverter
(element use : IGBT)

Etc


▪ Display window: Large Graphic Touch Screen for both Korean / English
▪ Built-in input and output isolation multi-volume transformer
▪ Parallel operation configuration of up to 3 units
▪ Remote monitoring: No-voltage contact, RS232C, 
RS485 Modbus, SNMP



System


Operation system
Control system
Double Conversion
(On Line) System
DSP (Digital Signal Processor) Control

Rated capacity


1phase 10 ~ 100kVA (Designated at the time of purchase)

Input(Rectifier/Sine waveform of charger part)


Input voltage
3phase 380V (Select 208/220/440/480V)
Input constant
3phase 3wire, 3phase 4wire
Input frequency
50 / 60Hz
Input distortion rate
3% or less voltage, 5% or less current
Input power factor
0.99 or more
Control system
PWM Converter (element use : IGBT)

Storage battery


Rated voltage
DC 360V (DC 110, 220, 240V, etc., can be changed)
Quantity
DC 360V - 12V 30Cells or 2V 180Cells

Output(Inverter part)


Output voltage
1phase 220V (110, 120, 208, 230V)
Voltage stability
±2% or less
Output waveform
sine wave
Output constant
1phase 2wire
Output frequency
50 / 60Hz
Frequency stability
±0.1% or less
Output distortion rate
→ linear load : ±3% or less

→ non-linear load : ±5% or less

Overload capacity
rated load 125% 10 minutes
Transient response
±5% or less
Transient response time
50ms or less (return within ±2%)
Load power factor
0.8 Lag
Overall efficiency
88% or more
Control system
PWM Inverter (element use : IGBT)

Etc


▪ Display window: Large Graphic Touch Screen for both Korean / English

▪ Built-in input and output isolation multi-volume transformer

▪ Parallel operation configuration of up to 3 units

▪ Remote monitoring: No-voltage contact, RS232C, RS485 Modbus, SNMP


XEONICS 

A. 16648 195-66, Saneop-ro, Gwonseon-gu, Suwon-si, Gyeonggi-do, Republic of Korea

T. +82-31-686-0300   ㅣ   F. +82-31-686-0310

E. xeonics@xeonics.co.kr

ⓒ 2022 XEONICS

XEONICS  A. 16648 195-66, Saneop-ro, Gwonseon-gu, Suwon-si, Gyeonggi-do, Republic of Korea

T. +82-31-686-0300   ㅣ   F. +82-31-686-0310   ㅣ   E. xeonics@xeonics.co.kr

ⓒ 2022 XEONICS