Products

UPS

ATOM3000S

5, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75

System


Operation system
Control system
Double Conversion
(On Line) System
μ- Processor Control

Rated capacity


1phase 5 ~ 75kVA

(Designated at the time of purchase)

Input(Rectifier/Sine waveform of charger part)


Input
voltage
3phase 380V
(Select 208/220/440/480V)
Input
constant
3phase 3wire / 3phase 4wire
Input
frequency
50 / 60Hz
Input
distortion rate
3% or less voltage
Control
system
6Pulse Rectifier
(element use : Thyristor)

Storage battery


Rated
voltage
DC 240V
(For voltage other than the rated voltage, please inquire.)
Quantity
DC 240V - 12V 20Cells or
2V 120Cells

Output(Inverter part)


Output
voltage
3phase 380V
(Select 208, 220, 440, 480V)
1phase 220V
(Select 110, 208V)

Voltage
stability
±2% or less
Output
waveform
sine wave
Output
constant
1phase 2wire
Output
frequency
50 / 60Hz
Frequency stability
±0.1% or less
Output
distortion rate 
→ linear load (±3% or less)

→ non-linear load (±5% or less)

Overload capacity
Rated load 125% 10 minutes
Transient response
±5% or less
Transient
response
time
50ms or less
(return within ±2%)
Load
power
factor
0.8 Lag
Overall
efficiency
80% or more
Control
system
PWM Inverter
(element use : IGBT)

Etc


▪ Display window: LCD
▪ Built-in input and output isolation multi-volume transformer
▪ Remote monitoring: No-voltage contact, RS232C, 
RS485, SNMP

System


Operation system
Control system
Double Conversion
(On Line) System
μ- Processor Control

Rated capacity


1phase 5 ~ 75kVA (Designated at the time of purchase)

Input(Rectifier/Sine waveform of charger part)


Input voltage
3phase 380V (Select 208/220/440/480V)
Input constant
3phase 3wire / 3phase 4wire
Input frequency
50 / 60Hz
Input distortion rate
3% or less voltage
Control system
6Pulse Rectifier (element use : Thyristor)

Storage battery


Rated voltage
DC 240V (For voltage other than the rated voltage, please inquire.)
Quantity
DC 240V - 12V 20Cells or 2V 120Cells

Output(Inverter part)


Output voltage
3phase 380V (Select 208/220/440/480V)
1phase 220V (Select 110/208V)
Voltage stability
±2% or less
Output waveform
sine wave
Output constant
1phase 2wire
Output frequency
50 / 60Hz
Frequency stability
±0.1% or less
Output distortion rate 
→ linear load : ±3% or less

→ non-linear load : ±5% or less

Overload capacity
rated load 125% 10 minutes
Transient response
±5% or less
Transient response time
40ms or less (return within ±2%)
Load power factor
0.8 Lag
Overall efficiency
80% or more
Control system
PWM Inverter (element use : IGBT)

Etc


▪ Display window : LCD

▪ Built-in input and output isolation multi-volume transformer

▪ Remote monitoring: No-voltage contact, RS232C, RS485, SNMP


XEONICS 

A. 16648 195-66, Saneop-ro, Gwonseon-gu, Suwon-si, Gyeonggi-do, Republic of Korea

T. +82-31-686-0300   ㅣ   F. +82-31-686-0310

E. xeonics@xeonics.co.kr

ⓒ 2022 XEONICS

XEONICS  A. 16648 195-66, Saneop-ro, Gwonseon-gu, Suwon-si, Gyeonggi-do, Republic of Korea

T. +82-31-686-0300   ㅣ   F. +82-31-686-0310   ㅣ   E. xeonics@xeonics.co.kr

ⓒ 2022 XEONICS