Products

Heavy Electric Machine

(BATTERY CHARGER/RECTIFIER/CONVERTER)

XBC2000

30, 50, 75, 100, 150, 200, 300, 400, 500, 600, 800, 900, 1000, 1200, 1500, 2000

System


Operation system
Charging method
Double Conversion
(On Line) System
Floating charging
or equal charging

Rated capacity


DC 110V, 30~1000A (Select DC 24/48/220V)

DC 125V, 30~2000A (Designated at the time of purchase)

Input


Input
voltage
3phase 380V
(Select 208/220/440/480V)
Input
constant
3phase 3wire
Input
frequency
50 / 60Hz
Input
distortion rate
3% or less voltage
Control
system
6Pulse Rectifier
(element use : Thyristor)

Storage battery


Rated
voltage
DC 110V
(For voltage other than the rated voltage, please inquire.)
Quantity
DC 110V - 12V 9Cells or
2V 55Cells

Output(Rectifier)


Output
voltage
DC 110V
(Select DC 24, 48, 220V)
Voltage
stability
±2% or less
Ripple
factor
2% (rms)
Overload capacity
Rated load 125% 10 minutes
Overall
efficiency
80% or more

Etc


▪ Display window: LED + Meter
▪ Floating charging voltage/equal charging voltage and discharging end voltage vary depending on the storage battery
▪ Supplement of the lowered output to suit the load through S.I.D composed of Diode, Magnetic Contactor, and DSP Controller.
▪ Remote monitoring: No-voltage contact, Transducer

▪ Built-in output Feeder is available(choice when making a purchase)

▪ KEPCO, District Heating, and so on. Plant Type (XBC2000)

System


Control system
Charging method
μ - Processor Control
Floating charging
or equal charging

Rated capacity


DC 110V, 30~1000A (Select DC 24/48/220V)

DC 125V, 30~2000A (Designated at the time of purchase )

Input


Input voltage
3phase 380V (Select 208/220/440/480V)
Input constant
3phase 3wire
Input frequency
50 / 60Hz
Input distortion rate
3% or less voltage
Control system
6Pulse Rectifier (element use : SCR)

Storage battery


Rated voltage
DC 110V (For voltage other than the rated voltage, please inquire.)
Quantity
DC 110V - 12V 9Cells or 2V 55Cells

Output(Rectifier)


Output voltage
DC 110V (Select DC 24/48/220V)
Voltage stability
±2% or less
Ripple factor2% (rms)
Overload capacity
rated load 125% 10 minutes
Overall efficiency
80% or more

Etc


▪ Display window: LED + Meter

▪ Floating charging voltage/equal charging voltage and discharging end voltage vary depending on the storage battery

▪ Supplement of the lowered output to suit the load through S.I.D composed of Diode, Magnetic Contactor, and DSP Controller.

▪ Built-in output Feeder is available (choice when making a purchase)

▪ Remote monitoring: No-voltage contact, Transducer

▪ KEPCO, District Heating, and so on. Plant Type (XBC2000)


XEONICS 

A. 16648 195-66, Saneop-ro, Gwonseon-gu, Suwon-si, Gyeonggi-do, Republic of Korea

T. +82-31-686-0300   ㅣ   F. +82-31-686-0310

E. xeonics@xeonics.co.kr

ⓒ 2022 XEONICS

XEONICS  A. 16648 195-66, Saneop-ro, Gwonseon-gu, Suwon-si, Gyeonggi-do, Republic of Korea

T. +82-31-686-0300   ㅣ   F. +82-31-686-0310   ㅣ   E. xeonics@xeonics.co.kr

ⓒ 2022 XEONICS