UPS
Products
UPS
XPS-3000
3kVA
System
Operation system | Control system |
Double Conversion (On Line) System | μ- Processor Control |
Rated capacity
1phase 3kVA
Input(Rectifier/Sine waveform of charger part)
Input voltage | 3phase 380V 1phase 380V |
Input constant | 1phase 2wire / 3phase 3wire |
Input frequency | 50Hz |
Input distortion rate | 3% or less voltage |
Control system | 6pwlse Rectifier (element use : Thyristor) |
Storage battery
Rated voltage | DC 240V |
Quantity | DC 240V - 12V 18AH 20Cells |
Output(Inverter part)
Output voltage | 1phase 220V |
Voltage stability | ±2% or less |
Output waveform | sine wave |
Output constant | 1phase 2wire |
Output frequency | 50Hz |
Frequency stability | ±0.1% or less |
Output distortion rate | → linear load (±3% or less) → non-linear load (±5% or less) |
Overload capacity | Rated load 125% 10 minutes |
Transient response | ±5% or less |
Transient response time | 40ms or less (return within ±2%) |
Load power factor | 0.8 Lag |
Overall efficiency | 80% or more |
Control system | PWM Inverter (element use : IGBT) |
Etc
▪ Display window: LCD
▪ Remote monitoring: No-voltage contact
System
Operation system | Control system |
Double Conversion (On Line) System | μ- Processor Control |
Rated capacity
1phase 3kVA
Input(Rectifier/Sine waveform of charger part)
Input voltage | 3phase 380V 1phase 380V |
Input constant | 1phase 2wire / 3phase 3wire |
Input frequency | 50Hz |
Input distortion rate | 3% or less voltage |
Control system | 6Pwlse Rectifier (element use : Thyristor) |
Storage battery
Rated voltage | DC 240V |
Quantity | DC 240V - 12V 18AH 20Cells |
Output(Inverter part)
Output voltage | 1phase 220V |
Voltage stability | ±2% or less |
Output waveform | sine wave |
Output constant | 1phase 2wire |
Output frequency | 50Hz |
Frequency stability | ±0.1% or less |
Output distortion rate | → linear load : ±3% or less → non-linear load : ±5% or less |
Overload capacity | rated load 125% 10 minutes |
Transient response | ±5% or less |
Transient response time | 40ms or less (return within ±2%) |
Load power factor | 0.8 Lag |
Overall efficiency | 80% or more |
Control system | PWM Inverter (element use : IGBT) |
Etc
▪ Display window : LCD
▪ Remote monitoring: No-voltage contact